Residential gas Power Vented Boilers

Boiler Company/Contractor in Mississauga, GTA, Toronto, Oakville   

Residential Hot Water Heaters                                                HOME                                           

 

Tel: 905-403-9914

SERVICE & MAINTENANCE

SITE MAP

REFERENCE LETTERS

REFERENCE LIST

CONTACT US

 

We service and install Residential and Commercial Boilers Contractors companies in Mississauga, Toronto, GTA, Etobicoke, Oakville & Burlington

Residential Boiler Venting

gas boilers    biolers mississauga 

Through the Wall                          Through the Chimney


Olsen Boiler,Boilers  

Boiler contractors installations service repair

 

Olsen Boilers

Warranty
Hot water boilers are backed by the most straightforward, comprehensive warranty in the industry - including a lifetime warranty on the entire heat exchanger, not just the sections. All other components are covered for one to five years from date of installation.

gas mississauga boilers    Olsen OMGB Cas Iron Atmospheric Vent Gas Boiler
    Olsen ODV-B Gas Fired Hot Water Boiler
    Olsen Quantum 90 Natural Gas Fired Boiler
    Olsen Quantum 90 - 200 Natural Gas Fired Boiler
<< Boilers

 

mississauga

OMGB Cast Iron Atmospheric Vent Gas Boiler

The OMGB Series boiler features an advanced heat exchanger design that utilizes atmospheric burners allowing it to be vented vertically through a chimney. This heat exchanger design combined with quality components such as a flue damper and electronic ignition helps the OMGB achieve fuel efficiencies up to 84.1%, making it an ideal choice for new or existing homes.

Key Features:

Quality Cast Iron Heat Exchanger

boiler

The OMGB utilizes cast iron construction because of its durability and efficient heat transfer capabilities. Cast iron sections and push nipples are an integral part of each OMGB heat exchanger. Dual thermal flow speeds heat transfer. Hot flueway gases pass around hundreds of staggered studs on the flueway wall, providing rapid heat transfer to the boiler water. Internal baffles agitate the circulating water, so it heats quickly and uniformly. Using only the highest quality cast iron and heat transfer designs ensure that the OMGB will provide many years of efficient and trouble-free operation.

Fuel Saving Components

power ventAdvanced engineering can be found in every part of a OMGB boiler. An optional "on-demand" ignition control eliminates wasted fuel associated with a continuously burning pilot light. In addition, an integrated automatic vent damper closes when the burner shuts off, preventing heat from leaving through the chimney saving fuel and heating costs.

 

Easy Installation and Maintenance

A compact design and special packaging features make the OMGB boiler easy to install and service. An integrated flue collector and draft hood allows for easier installation in cramped areas. The pilot assembly is easily accessible, located on the orifice side of the burners, out of the main combustion area. The OMGB comes factory-assembled, wired and tested to eliminate costly field assembly and reduce installation time.

Stainless Steel Burners

Corrosion resistant atmospheric stainless steel burners are incorporated into each OMGB boiler delivering uniform flame patterns that optimize combustion efficiency and quiet operation.

Manufacturers Limited Lifetime Warranty

Olsen HVAC backs its residential, cast-iron heat exchangers with a Limited Lifetime Warranty. This Warranty is meant to protect your investment, but is also offered to illustrate our commitment to customer satisfaction.

<< Olsen Boilers

Olsen ODV-B Gas Fired Hot Water Boiler

Gas-Fired/Natural or Propane

The ODV-B series boiler combines high efficiency and venting flexibility with a compact design that allows installation in virtually any residential application. With quality components such as cast-iron heat exchangers and stainless steal burners, the ODV-B is an ideal choice for new or existing homes.

Key Features:

Venting and Installation Flexibility

The ODV-B Series boiler can be vented vertically up a chimney or horizontally through an exterior wall making it a convenient and cost effective choice for a variety of applications. Standing less than 31 inches high, this low profile boiler fits into areas that other boilers can not. The ODV-B is also an ideal choice when converting a home from electric heat to a hot water system.

Cast Iron Heat Exchanger

The ODV-B utilizes cast iron construction because of its durability and efficient heat transfer capabilities. Cast iron sections and push nipples are an integral part of each ODV-B heat exchanger. Using only the highest quality cast iron and heat transfer designs, the ODV-B will provide many years of efficient and trouble-free operation.

High Energy Efficiency and Lower Heating Costs

With efficiency ratings as high as 83%, the ODV-B provides increased energy savings resulting in lower fuel bills. With the potential cost savings this represents, the ODV-B boiler will pay for itself in a few short years.

<< Olsen Boilers

gas    Olsen Quantum 90 Natural Gas Fired Boiler      

Features & Benefits of the Quantum 90 Natural Gas Fired Boilers:gas mississauga

 

The Olsen Quantum 90 Hot Water Boiler achieves the optimum combination of high efficiency, innovative technology and simplicity of design, making it the ideal choice for today's heating customer.

gas contractor

Remarkable 90% AFUE Efficiency
The Q90 pays for itself with substantial annual fuel savings. Its efficiency is increased beyond 90% when used in low temperature systems, such as radiant systems.

Revolutionary Cast Aluminium Heat Exchanger
Transfers heat three times faster with greater thermal conductivity than conventional cast iron. It produces enormous gains in heat-up speed and operating efficiency.

Safe, Economical CPVC and PVC Vent Pipe
Cooled flue gas can be safely vented through inexpensive readily available and easy to install PVC.

Sealed Combustion, Direct-Vent System
Unlike conventional residential atmospheric and induced draft boilers, the Q90 draws fresh air from outdoors for combustion, instead of air from inside the home. Therefore it does not compete with building occupants for its air supply. With this design the Q90 runs quieter than a traditional boiler.

Simplified Controls
The Quantum 90’s simple design is engineered to maximize reliability. The Q90 incorporates an integrated boiler control for operation, safety and diagnostics. A High Temperature Limit Control is included for additional safety. Ignition is provided by a hot surface igniter and a single stage gas valve. A single pressure switch ensures air intake and exhaust vents are clear. All components are easily accessible through the removable door.

Environmentally Friendly
The Q90's direct-vent system, premix gas burner and low flame temperature substantially reduce CO and NOx emissions (acid rain and smog components).

<< Olsen Boilers

    Olsen Quantum 90 - 200 Natural Gas Fired Boiler

Features & Benefits of the quantum 90-200 natural gas fired boiler:contractors

Toronto, Etobicoke, Mississauga, Streetsville, South Brampton, Oakville, Burlington

 

The Quantum 90-200 Hot Water Boiler by Olsen HVAC achieves the optimum combination of high efficiency, innovative technology and simplicity of design, making it the ideal choice for today's heating customer.

Remarkable 90% AFUE Efficiency
The Q90-200 dramatically reduces fuel consumption and pays for itself with substantial annual fuel savings. Its efficiency is increased beyond 90% when used in low temperature systems, such as radiant systems.

Revolutionary Cast Aluminium “Mono Block” Heat Exchanger
This one-piece heat exchanger design eliminates leaks that can occur due to section interface with sectional heat exchangers. The greater thermal conductivity of cast aluminium transfers heat three times faster than conventional cast iron, producing enormous gains in heat-up speed and operating efficiency. Also, the packaged boiler weighs only 220 pounds for easier installation.

Simplified Controls
The Quantum 90-200’s control design is engineered to maximize reliability. The Q90-200 incorporates an integrated boiler control with high limit and low water cut-off for operation, safety and diagnostics. Ignition is provided by a hot surface igniter and a single stage gas valve. Dual switches ensure air intake and exhaust vents are clear. All components are easily accessible through the removable door.

Sealed Combustion, Direct-Vent System
Unlike conventional atmospheric boilers, the Q90-200 draws fresh air from outdoors for combustion, instead of air from inside the home. Therefore it does not compete with building occupants for its air supply. With this design the Q90-200 runs quieter and more efficiently than a traditional boiler.

Safe, Economical CPVC and PVC Vent Pipe
Cooled flue gas can be safely vented through inexpensive readily available and easy to install PVC, after 5' of CPVC provided with the unit. The air intake also utilizes PVC pipe.

Environmentally Friendly
The Q90-200's direct-vent system, premix gas burner and low flame temperature reduce CO and NOx emissions (acid rain and smog components) by more than 30% and 50% respectively.

^^Boilers    << Olsen Boilers       

[Heating]  [Furnaces]  [Fireplaces]  [Radiant Floor Heating]  [Hot Water Heaters]  [Chimney Liners] 

[Air Conditioning]    [Central Air Conditioning]    [Ductless Air Conditioning]    [Fireplaces]    [Air Quality]   

[About Us]    [Contact Us]    [Order Filters]

[References]    [Site Map]

Boiler Installation coverage:

Toronto, Etobicoke, Mississauga, Streetsville, South Brampton, Oakville, Burlington

Copyright 1998 weinstall.ca

Boilers installation contractors O,t.