These are some common Trane furnace error codes.

Flashing slow:  Normal no call for heat
Flashing fast:  Normal call for heat
Continuous on:  Replace control
Continuous off:  Check for power
2 flashes:  System lockout (no flame) or reversed polarity
3 flashes:  Pressure switch problem
4 Flashes:  Thermal (limit) protection off
5 Flashes:  Flame sensed with gas valve off 



Flashing Slow Normal - No call for Heat from thermostat
Flashing Fast Normal - Call for Heat from thermostat
Continuous ON Control Board Bad - needs replaced
Continuous OFF Check Power
2 Flashes System Lockout (Retries or Recycles exceeded)
3 Flashes Vent Pressure Switch Error
4 Flashes Open High Temperature Limit Device
5 Flashes Flame sensed when no flame should be present
6 Flashes 115 Volt AC power reversed or Poor Grounding
7 Flashes Gas valve circuit error
8 Flashes Low flame sense signal



Flashing Slow Normal - No call for Heat from thermostat
Flashing Fast Normal - Call for Heat from thermostat
Continuous ON Control Board Bad - needs replaced
Continuous OFF Check Power
2 Flashes System Lockout (Retries or Recycles exceeded)
3 Flashes Vent Pressure Switch Error
4 Flashes Open High Temperature Limit Device
5 Flashes Flame sensed when no flame should be present
6 Flashes 115 Volt AC power reversed or Poor Grounding
7 Flashes Gas valve circuit error
8 Flashes Low flame sense signal
9 Flashes Check ignitor circuit and line "N" to 24 VAC Common voltage ( < 2 volts)